MpAssetIntUIJobListOutputType

<< Click to Display Table of Contents >>

Navigation:  »No topics above this level«

MpAssetIntUIJobListOutputType

mapp Services V5.16

List of states from the current shift and associated navigation.

For an explanation of the individual parameters and how they are calculated, see section Calculating asset intensity.

Parameter

Data type

Description

JobStartTime

ARRAY[0..19] of DATE_AND_TIME

Start times of the jobs

JobEndTime

ARRAY[0..19] of DATE_AND_TIME

End times of the jobs

JobName

ARRAY[0..19] of STRING[20]

Names of the jobs

CurrentUser

ARRAY[0..19] of STRING[50]

Currently logged-in user

AdditionalData

ARRAY[0..19] of STRING[255]

Additional information

TotalPieces

ARRAY[0..19] of UDINT

Total number of products per job

GoodPieces

ARRAY[0..19] of UDINT

Total number of good products per job

RejectPieces

ARRAY[0..19] of UDINT

Total number of rejected products per job

BadPieceRate

ARRAY[0..19] of REAL

Total number of bad products per job

TotalTime

ARRAY[0..19] of MpAssetIntTimeType

Total time per job

ScheduledDowntime

ARRAY[0..19] of MpAssetIntTimeType

Scheduled downtime per job

UnscheduledDowntime

ARRAY[0..19] of MpAssetIntTimeType

Unscheduled downtime per job

Uptime

ARRAY[0..19] of MpAssetIntTimeType

Uptime per job

GoodProductionTime

ARRAY[0..19] of MpAssetIntTimeType

Good production time per job

NominalProductionTime

ARRAY[0..19] of MpAssetIntTimeType

Production time at machine's nominal speed

NominalProductionRate

ARRAY[0..19] of REAL

Production rate at machine's nominal speed

ScheduledDowntimeRate

ARRAY[0..19] of REAL

Scheduled downtime rate

UnscheduledDowntimeRate

ARRAY[0..19] of REAL

Unscheduled downtime rate

ProductionRate

ARRAY[0..19] of REAL

Production rate

PageUp

BOOL

Jumps to the start of the current page and then scrolls up one page at a time The size of the page is defined using parameter "OutputListSize" in structure MpAssetIntJobListUISetupType.

VC4 connection: Datapoint from Button / Type: SetDatapoint / SetValue: 1 / ResetValue: 0

PageDown

BOOL

Jumps to the end of the current page and then scrolls down one page at a time The size of the page is defined using parameter "OutputListSize" in structure MpAssetIntJobListUISetupType.

VC4 connection: Datapoint from Button / Type: SetDatapoint / SetValue: 1 / ResetValue: 0

StepUp

BOOL

Selects the previous entry in the list

VC4 connection: Datapoint from Button / Type: SetDatapoint / SetValue: 1 / ResetValue: 0

StepDown

BOOL

Selects the next entry in the list

VC4 connection: Datapoint from Button / Type: SetDatapoint / SetValue: 1 / ResetValue: 0

RangeStart

REAL

Shows a bar indicating which part of the list is currently being displayed. Used for the starting value of "Range" for a scaled element in the HMI application. This scaled element should correspond to the (possible) size of the list. "Range" should correspond to the number of entries that are displayed on one page.

VC4 connection: StartDatapoint from Scale

RangeEnd

REAL

Shows a bar indicating which part of the list is currently being displayed. Used for the ending value of "Range" for a scaled element in the HMI application. This scaled element should correspond to the (possible) size of the list. "Range" should correspond to the number of entries that are displayed on one page.

VC4 connection: EndDatapoint from Scale

ShiftName

ARRAY[0..19] of STRING[20]

Name of the current shift.