<< Click to Display Table of Contents >> Navigation: »No topics above this level« MpAssetIntUIJobListOutputType |
mapp Services V5.16
List of states from the current shift and associated navigation.
For an explanation of the individual parameters and how they are calculated, see section Calculating asset intensity.
Data type |
Description |
|
JobStartTime |
ARRAY[0..19] of DATE_AND_TIME |
Start times of the jobs |
JobEndTime |
ARRAY[0..19] of DATE_AND_TIME |
End times of the jobs |
JobName |
ARRAY[0..19] of STRING[20] |
Names of the jobs |
CurrentUser |
ARRAY[0..19] of STRING[50] |
Currently logged-in user |
AdditionalData |
ARRAY[0..19] of STRING[255] |
Additional information |
TotalPieces |
ARRAY[0..19] of UDINT |
Total number of products per job |
GoodPieces |
ARRAY[0..19] of UDINT |
Total number of good products per job |
RejectPieces |
ARRAY[0..19] of UDINT |
Total number of rejected products per job |
BadPieceRate |
ARRAY[0..19] of REAL |
Total number of bad products per job |
TotalTime |
ARRAY[0..19] of MpAssetIntTimeType |
Total time per job |
ScheduledDowntime |
ARRAY[0..19] of MpAssetIntTimeType |
Scheduled downtime per job |
UnscheduledDowntime |
ARRAY[0..19] of MpAssetIntTimeType |
Unscheduled downtime per job |
Uptime |
ARRAY[0..19] of MpAssetIntTimeType |
Uptime per job |
GoodProductionTime |
ARRAY[0..19] of MpAssetIntTimeType |
Good production time per job |
NominalProductionTime |
ARRAY[0..19] of MpAssetIntTimeType |
Production time at machine's nominal speed |
NominalProductionRate |
ARRAY[0..19] of REAL |
Production rate at machine's nominal speed |
ScheduledDowntimeRate |
ARRAY[0..19] of REAL |
Scheduled downtime rate |
UnscheduledDowntimeRate |
ARRAY[0..19] of REAL |
Unscheduled downtime rate |
ProductionRate |
ARRAY[0..19] of REAL |
Production rate |
PageUp |
BOOL |
Jumps to the start of the current page and then scrolls up one page at a time The size of the page is defined using parameter "OutputListSize" in structure MpAssetIntJobListUISetupType. VC4 connection: Datapoint from Button / Type: SetDatapoint / SetValue: 1 / ResetValue: 0 |
PageDown |
BOOL |
Jumps to the end of the current page and then scrolls down one page at a time The size of the page is defined using parameter "OutputListSize" in structure MpAssetIntJobListUISetupType. VC4 connection: Datapoint from Button / Type: SetDatapoint / SetValue: 1 / ResetValue: 0 |
StepUp |
BOOL |
Selects the previous entry in the list VC4 connection: Datapoint from Button / Type: SetDatapoint / SetValue: 1 / ResetValue: 0 |
StepDown |
BOOL |
Selects the next entry in the list VC4 connection: Datapoint from Button / Type: SetDatapoint / SetValue: 1 / ResetValue: 0 |
RangeStart |
REAL |
Shows a bar indicating which part of the list is currently being displayed. Used for the starting value of "Range" for a scaled element in the HMI application. This scaled element should correspond to the (possible) size of the list. "Range" should correspond to the number of entries that are displayed on one page. VC4 connection: StartDatapoint from Scale |
RangeEnd |
REAL |
Shows a bar indicating which part of the list is currently being displayed. Used for the ending value of "Range" for a scaled element in the HMI application. This scaled element should correspond to the (possible) size of the list. "Range" should correspond to the number of entries that are displayed on one page. VC4 connection: EndDatapoint from Scale |
ShiftName |
ARRAY[0..19] of STRING[20] |
Name of the current shift. |
|
|