This function block displays the energy data in graphic form.

Function block

mpenergycoreui

Interface

I/O

Parameter

Data type

Description

IN

MpLink

Pointer to MpComIdentType

Connection to mapp configuration (MpLink of an MpEnergyCore configuration)

IN

Enable

BOOL

The function block is active as long as this input is set.

IN

ErrorReset

BOOL

Resets function block errors.

IN

UISetup

MpEnergyCoreUISetupType

Used to configure the elements connected to the HMI application.

IN

UIConnect

Pointer to MpEnergyCoreUIConnectType

This structure contains the parameters needed for the connection to the HMI application.

OUT

Active

BOOL

Function block active.

OUT

Error

BOOL

Error occurred during execution.

OUT

StatusID

DINT

Status information.

OUT

Info

MpEnergyInfoType

Additional function block information.

mapp concept

Section mapp components explains how mapp components are structured. In addition, it provides important notes for correctly using mapp components (e.g. for downloads).

Topics in this section:

Description