After the changes are downloaded, the program can be tested. Monitor mode is enabled.
|
|
Function block MpOeeCore, as well as the variables for the number of pieces and the number of rejects, have already been added to the Watch window. The current OEE value can be read from the output parameters of MpOeeCore. The OEE values can be saved to the data storage device using command "Export".
|
|
The exported files are located on the previously defined data storage device.
The timeline displays all events that occur during a shift.
An entry is created for each shift in the shift statistics. All OEE-relevant data is included for the respective shift, e.g. OEE value, performance, availability, start and end time of the shift, etc.
|
|