This data type describes PGN EEC2 (electronic engine control 2).

Parameter

Data type

Description

EstPumpingPercentTorque

SINT

The calculated torque specifies the estimated amount of torque loss due to the engine ventilation system.

ActlMaxAvailableEngPercentTorque

REAL

This is the maximum amount of torque that the engine can deliver immediately as a percentage of the reference engine torque.

SCRThermalManagementActive

MpJ1939SCRTMAEnum

Specifies whether the exhaust gas temperatures have been increased to regenerate the SCR aftertreatment system or to prepare for regeneration of the SCR aftertreatment system.

DPFThermalManagementActive

MpJ1939DPFTMAEnum

Indicates that the exhaust gas temperatures have been increased for regeneration of the diesel particulate filter aftertreatment system or for preparation of regeneration of the diesel particulate aftertreatment system.

MmntaryEngMaxPowerEnableFeedback

MpJ1939MEMPEFEnum

Specifies whether the maximum engine power is currently activated.

VhcleAccelerationRateLimitStatus

MpJ1939VARLSEnum

State of the system that limits the maximum vehicle forward acceleration.

AccelPedalPos2

REAL

The ratio of the actual position of the second analog engine speed/torque request input device (such as an accelerator pedal or throttle lever) to the maximum position of the input device.

RemoteAccelPedalPos

REAL

The ratio of the actual position of the remote analog engine speed/torque request input device (such as an accelerator pedal or throttle lever) to the maximum position of the input device.

EngPercentLoadAtCurrentSpeed

SINT

The ratio of the actual engine percentage torque (indicated) to the maximum indicated torque available at the current engine speed is limited to zero torque during engine braking.

AccelPedalPos1

REAL

The ratio of the actual position of the analog engine speed/torque request input device (such as an accelerator pedal or throttle lever) to the maximum position of the input device.

AccelPedal2LowIdleSwitch

MpJ1939AP2LISEnum

Switching signal indicating the state of the low idle switch on accelerator pedal 2.

RoadSpeedLimitStatus

MpJ1939RSLiSEnum

State of the system for limiting the maximum vehicle speed.

AccelPedalKickdownSwitch

MpJ1939APKSEnum

Switching signal indicating whether the accelerator pedal kick-down switch is open or closed.

AccelPedal1LowIdleSwitch

MpJ1939AP1LISEnum

Switching signal indicating the state of the low idle switch on accelerator pedal 1.

Status

MpJ1939PGNStatusEnum

State of the parameter group number.