This data type describes PGN AT1OG1 (aftertreatment 1 / output gas 1).

Parameter

Data type

Description

O2Snsr1PreliminaryFMI

INT

Value measured by the oxygen sensor for the aftertreatment outlet.

NOxSnsr1SelfDiagStatus

MpJ1939NOS1SDSEnum

Status of NOx sensor ATO1 (aftertreatment output bank 1).

NOxSnsr1PreliminaryFMI

INT

Value measured by the NOx sensor for the aftertreatment outlet.

Snsr1HtrCtrl

MpJ1939S1HCEnum

Indicates the heating status during the warm-up process. After receiving a switch-on command, the gas sensor is started up according to a profile defined by the manufacturer.

Snsr1HtrPreliminaryFMI

INT

Specifies the value measured in the outlet exhaust gas sensor heater – either NOx or O2.

WRPercentO21ReadingStable

MpJ1939WRPO21RSEnum

Specifies whether the percentage of the oxygen measured value of the aftertreatment outlet gas sensor – either NOx or O2 – is stable as determined by the manufacturer's control software in exhaust bank 1.

NOx1ReadingStable

MpJ1939NO1RSEnum

Specifies whether the NOx measured value of the aftertreatment outlet NOx sensor is stable as determined by the manufacturer's control software in exhaust bank 1.

Snsr1AtTemp

MpJ1939S1ATEnum

Specifies whether the heating element of the aftertreatment outlet gas sensor – either NOx or O2 – for accurate measurements in exhaust bank 1 is within the range specified by the manufacturer.

Snsr1PwrInRange

MpJ1939S1PIREnum

Specifies whether the power supplied to the aftertreatment outlet gas sensor – either NOx or O2 – is within the manufacturer's specification in exhaust bank 1.

PercentO21

REAL

The actual oxidation factor (oxygen percentage) of the gas in the exhaust gas flow.

NOx1

REAL

The amount of combined NO and NO2 in the exhaust gas leaving the aftertreatment system.

Status

MpJ1939PGNStatusEnum

State of the parameter group number.